User's Manual
Figure 30: Select Facility window
8. Select a handset model and click OK.
9. Select and specify other properties if necessary (e.g. ‘Description’).
10. Click OK to save the new device.
Several devices can be added to a group, as group members. Working with groups and group
members, as well as further details on supported output devices can be found in DECT
Messenger Fundamentals, NN43120–120.
Publishing or discarding changes
When you are working with eCONFIG, changes to users, devices, and groups are published
immediately. However, structural changes to sites, areas, and modules require the local
database to be copied back over the production database on the DECT Messenger Server.
Note:
Publishing overwrites any changes made to the production database after eCONFIG created
its local copy during start up. You must ensure that users did not make changes to the
production database after the local copy was created.
When you want to end the configuration process, select File > Exit from the eCONFIG main
menu. You are then asked if you want to apply the configuration changes. Click Yes to apply
the changes or No to cancel.
Before you can publish the new configuration, you must ensure the current database is not in
use. This means that all DECT Messenger modules must be stopped. Before stopping a
production environment, take into consideration that all pending alarms are cleared at restart.
Getting started with DECT Messenger
60 DECT Messenger Installation and Commissioning — Book 1 March 2012
Comments? infodev@avaya.com