User's Manual
Figure 134: Digital Output module information
Note:
When the value of a contact changes from Off to On or from On to Off, the Before and After
fields are updated with the status of the contact before the change occurred and the status
of the contact after the change occurred. The Change field is also updated with the new
value.
Note:
You can also change the status of the contacts to On or Off by using the mouse to drag the
switch to the On or Off position. This must be carried out only while installing or testing. In
most environments, the eKERNEL application is responsible to activate or deactivate the
alarm condition of the discrete outputs. You can however manually reset a status of a
contact, for example, if manual intervention is required.
Logging
The eIO module provides logging facilities, both on-screen and on log files on disk.
The on-screen logs are visible through the Logging tab, as shown in
Figure 135: eIO
logging on page 187.
Module - eIO
186 DECT Messenger Installation and Commissioning — Book 1 March 2012
Comments? infodev@avaya.com