User's Manual
eWEB parameters 417
technical specification. Nortel recommends that you keep the message
length less than or equal to the maximum length defined in the associated
eKERNEL_ALARM table.
*FREE is the only other valid entry. This keyword enables the end user
to enter a message.
An authorized of an entry typically found in this field is as follows:
EVACUATION is active
WSC_Min_dev_cnt_str
This field specifies the minimum number of devices that must be selected
from the group by the end user, before a script message can be activated.
The only other valid entry in the current release is *ALL; therefore, all
devices from the group receive the message, so the end user does not
have the opportunity to select devices.
Warning: you must not specify a value larger then the number of devices
present in the group.
Note: In the current release, this parameter has nothing to do with the
number of devices that must receive the message before clearing the
message for all other devices from the group.
An authorized of an entry typically found in this field is as follows: *ALL
WSC_Max_Active_n
This field specifies the maximum number of times this script message can
be active. The keyword *NOMAX can be used to indicate there is no limit.
An authorized of an entry typically found in this field is as follows: 1 (for
EVACUATION) or *NOMAX (for informative messages)
WSC_Currently_Active_n
This field specifies the number of script messages currently active.
This field is used by the eKernel application, and has nothing to do with
configuration of the database.
WSCA_Comments_str
This field can be used by an administrator to enter remarks. The field is
informational only.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.