User's Manual

eKERNEL_SITE parameters 383
For more information, see the user manual of the internal serial watchdog
page 9 till 13.
An authorized of an entry typically found in this field is as follows: 0x21
CFG_INRQS_id_n
This field specifies a value that is used internally by eKERNEL, and you
must not change the value unless explicitly instructed to do so. The
value stored in CFG_INRQS_id_n is used to generate unique numbers
to incoming message requests. Manipulation of this value can result in
system malfunction. The value is used to generate unique keys in the
Messenger_DATA database table RQS_IN. Resetting the value without
cleaning up RQS_IN can result in system failure and is unsupported.
ATTENTION
Because table values are, for performance reasons, retrieved at startup
of eKERNEL, and committed at close down of eKERNEL, never stop the
eKERNEL using any method other than gracefully shutting down the application
with the close button. Abnormal shutdown can result in problems when the
system is started. Nortel recommends the use of a UPS. Problems due to
system power failure are unsupported.
An authorized of an entry typically found in this field is as follows: 2392
(never change the current value manually)
CFG_OUTRQS_id_n
This field specifies a value that is used internally by eKERNEL and you
must not change the value unless explicitly instructed to do so. The value
stored in CFG_OUTRQs_id_n is a number that is used to generate unique
numbers to outgoing message requests. Manipulation with this value can
result in system malfunction. The value is used to generate unique keys in
the Messenger_DATA database. Resetting the value without cleaning up
the appropriate database can result in system failure and is unsupported.
ATTENTION
Because table values are, for performance reasons, retrieved at startup
of eKERNEL, and committed at close down of eKERNEL, never stop the
eKERNEL using any method other than gracefully shutting down the application
with the close button. Abnormal shutdown can result in problems when the
system is started. Nortel recommends the use of a UPS. Problems due to
system power failure are unsupported.
An authorized of an entry typically found in this field is as follows: 4 (never
change the current value manually)
CFG_Comments_str
This field provides space for the administrator to enter comments, such as
reminder information, describing, for authorized, the full name of the site.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.