User's Manual
352 Table: eKERNEL_GROUP_MEMBER
Table 41
Supported output applications
GRP_From_str
This value specifies an hour and time in the format xx:xx. The valid range
is 00:00 to 23:59; values outside this range produce unpredictable results.
GRP_From_str denotes the start of the time interval where the defined
device is an active member of the specified group GRP_Name_str. For
authorized, 00:00 indicates the group-member is active at midnight, and
12:00 indicates the group-member starts at noon. The active period ends
at the time specified in GRP_To_str.
An authorized of an entry typically found in this field is as follows: 00:00
GRP_To_str
This value specifies an hour and time in the format xx:xx. The valid range
is 00:00 to 23:59; values outside this range produce unpredictable results.
GRP_To_str denotes time when the defined device ceases to be an active
member of the specified group GRP_Name_str. For authorized, 23:59
indicates the group-membership expires at midnight, and 12:00 indicates
that the group-membership expires at noon. The active time period begins
at the time specified in GRP_From_str.
Note 1: GRP_From_str can be larger than GRP_To_str: In this case, a
job can start at 21:00 and end at 06:00 (night-shift).
Note 2: A device can be active from for more than one period of time
on a given day. For authorized: 08:00-12:00 and 13:15-17:30; in this
case, two group members must be defined, one of 08:00-12:00 and
another with 13:15-17:30.
To clarify the possible values, authorizeds are shown in Table 42 "Group
member schedule authorizeds:" (page 353).
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.