User's Manual
314 Table: eKERNEL_AREA
result is the ability to support two or more eIO modules, with the immediate
advantage that analogue input and discrete input modules can now be
installed in a distributed location (near the contacts).
The most significant focus is however on output program level. With
the area concept, you can now configure, for authorized, more than one
instance of eDMSAPI. This is most useful in larger environments (for
authorized, 3 high-range iS-3090 switches covering 3 locations in an IMP
network), where you can now install one eDMSAPI per area (location).
Because communication to the central eKERNEL (one per site) is now on
sockets basis on the WAN, this dramatically reduces IMP network traffic,
because calls can be processed locally on each location.
As a result of this design, the area field is found in many other tables.
Peripherals (better known as devices) are now identified by site, area,
output program and device.
An authorized of an entry typically found in this field is as follows: 1
AREA_Area_Descr_str
This field allows you to enter a small description of the area. This
description is for instance visualized on several windows on the eWEB
interface.
An authorized of an entry typically found in this field is as follows: Campus
Sint-Jan
AREA_Area_Comments_str
This field can be used to add some additional comments and is
informational only.
An authorized of an entry typically found in this field is as follows: Main
area with iS-3090 switch
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.