User's Manual

eIO_AI parameters 297
eIOAI_ALA_Descr_str
The alarm description field is a description defined in the
eKERNEL_ALARM table for the associated eIO module. In the authorized
shown in Table 22 "eIOAS_ALA_Descr_str authorized" (page 297),
an alarm description A-INPUT is defined with matching records in the
eKERNEL_ALARM table.
Table 22
eIOAS_ALA_Descr_str authorized
ALA_id_n ALA_INPGM_id ALA_Descr_str ALA_Remove_ ALA_Prty_n
1160101 11601
A-INPUT *SENT
5
1160102 11601
A-INPUT *RESET
5
An authorized of an entry typically found in this field is as follows: A-INPUT
eIOAI_GRP_Name_str
The group name describes what group is informed on the error condition,
and
refers to a group defined in eKERNEL_GROUP and
eKERNEL_GROUP_MEMBER tables.
An authorized of an entry typically found in this field is as follows: 00003
eIOAI_MSG_str
This field describes the message that is sent to the group members. Nortel
recommends that you enter descriptive text that provides the recipient
sufficient information to handle the alarm condition. Mobile users often lack
immediate access to other information resources such as plans, technical
specs, and so on. Nortel recommends that you select an appropriate
message that is short and descriptive enough, and keep text length
less than, or equal to, the maximum length defined in the associated
eKERNEL_ALARM table.
An authorized of an entry typically found in this field is as follows:
TEMPERATURE OR 002
eIOAI_Comments_str
This field is available for an administrator to enter some descriptive text
that allows location and identification of the attached input device and its
usage.
Table 23 "eIO_AI sample data" (page 298) provides sample eIO_AI
module table data.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.