User's Manual

296 Table: eIO_AI
measurement en the measured input range. Nortel recommends that you
first test the peripherals with the FieldPoint Explorer prior to configuring
and taking eIO into production.
Note:
Check your operating system settings to find out which decimal
separator is in use. Nortel recommends that you set the operating
system to the country specific values, thus the locale Belgium (Dutch) in
Belgium, even when an English operating system is installed. These
regional settings result in internal usage of decimal separator symbols in
the form of period (.) or comma (,). If your system is set up with comma
(,) as decimal separator, a comma (,) must also be specified when
values are entered in the database.
An authorized of an entry typically found in this field is as follows:
20,000000
eIOAI_Max_S_str
The value specifies the analogue level measured on a contact to reset a
plus-level alarm.
If plus-level alarms are to be disabled a 99,999999 value can be specified.
Note:
All values must be specified in format 00,000000 with 2 digits
before the decimal separator and 6 digits after the decimal separator.
The decimal separator must be set according to the operating system
regional settings.
Refer to the FieldPoint Explorer documentation for more information on
the configuration of the FP-AI-100 module. Each channel can individually
be set according to the attached input, and allow specifying the unit of
measurement en the measured input range. Nortel recommends that you
first test the peripherals with the FieldPoint Explorer prior to configuring
and taking eIO into production.
Note: Check your operating system settings to find out which decimal
separator is in use. Nortel recommends that you set the operating
system to the country specific values, thus the locale Belgium (Dutch) in
Belgium, even when an English operating system is installed. These
regional settings result in internal usage of decimal separator symbols in
the form of period (.) or comma (,). If your system is set up with comma
(,) as decimal separator, a comma (,) must also be specified when
values are entered in the database.
When values are entered in the database.
An authorized of an entry typically found in this field is as follows:15,000
000.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.