User's Manual

eESPA parameters 273
If more than one address must be polled, the addresses must be
separated with a ^ sign. In this release, only a point to point link is
supported, so only one address can be specified.
An authorized of an entry typically found in this field is as follows: 2
eESPA_LocalAddress_n
This field specifies the address of the local espa interface.
An authorized of an entry typically found in this field is as follows: 1
eESPA_ExternalAddress_n
This field specifies the address of the remote station.
One eESPA interface is linked with one area, so is linked to only one
remote station. If more than one station can receive are sent espa alarms,
more areas must be configured in the configuration database.
An authorized of an entry typically found in this field is as follows: 2
eESPA_DataId_Group_str
Use this field to set the relationship between the DECT MessengerDevice
or Group and the data identifier of the espa record that specifies the
call address if eESPA acts as input program, so only relevant if eESPA
receives external data from the espa infrastructure.
If the eESPA module acts as input program: The eESPA module
receives espa records. Each espa record received must be translated to a
valid message request, and sent to the eKERNEL application.
The eESPA_DataId_Group_str field specifies the Data Identifier (normally
1) of the espa record that specifies the group. This group refers to the field
GRP_Descr_str of eKERNEL_GROUP table.
In the following authorized, data identifier 1 (call address) is defined as
eESPA_DataId_Group_str.
Table 15
Espa record: SOH1STX1US12345RS2USThe messageRS3US9RS4US3RS6U
S3ETXBCC
(SOH) Start of header
STX Start of text
ETX End of text
US Unit separator
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.