User's Manual

376 Module - eFR
The default value is 600 seconds
The minimum value is 60 seconds. Every minute a verification cycle
takes place. When a value smaller than 60 is configured, the system
adjusts it to 60 seconds
The maximum value is 86400 seconds, so once a day a verification
cycle takes place. When a larger value than 86400 is configured, the
system will adjust to 86400 seconds.
Note: The processing cycle takes some time, for example PING
to a large number of systems that are not responding increases
processing time. Since the interval effects the time between ending
the previous verification and starting a new verification, the exact
frequency is somewhat larger than the specified interval, depending on
the processing time.
Monitoring type DISK
The monitoring of disk drives is configured through the section in the XML
file shown in the next figure.
Figure 107
Monitoring type DISK
The opening tag <DISK> and the closing tag </DISK> provide space for
configuring the drives that must be monitored. You can define each drive
that needs to be monitored in the section between </Drives>.