User's Manual
312 Module - eCAP
In many cases the distance between the DECT Messenger and the
external-alarm system is relatively small, so no extra hardware is needed.
In some conditions hardware is needed, such as, when RS-232-C
limitations apply (for example, at 9600 baud maximum limit of 9 metres).
In some cases galvanic isolation is requested, or base-band modems,
SOPHO LAM, CISCO equipment, and so on are needed to bridge the
distance between the DECT Messenger and the alarm system.
Once a link is established between eCAP and the alarm system, the eCAP
handles further communications and informs eKERNEL when relevant
information is to be exchanged.
Functional description
In general, eCAP is designed to provide eKERNEL with alarm information.
This is carried out using a <msgrqs> message request. For some
interfaces eKERNEL must send feedback to the alarm system, a process
that is handled through <msgrpy> message reply request.
ATTENTION
The eCAP module is compatible with a number of alarm system installations.
However, many of the supported vendors offer a broad variety of hardware
and software environments, all of which are not necessarily compatible with
eCAP. For example, the fact that one NIRA serial protocol is implemented does
not mean that every version of serial input from NIRA is compatible.Ensure
that a specific alarm-system model is supported by DECT Messenger before
purchasing or installing it. In most cases manufacturers are not using the
same standard for all of their equipment, so obtain information on protocols
and specifications. Nortel recommends pre-sales consultation. If necessary,
a modification of the current release of eCAP can be made to embed new
protocols.
The most typical protocols are listed in Table 9 "Supported
manufacturer/model protocols" (page 312) and described in more detail
in the pages following the table. Refer to the protocol specifications of
each vendor for more information, as detailed protocol issues are beyond
the scope of this document. The information in Table 9 "Supported
manufacturer/model protocols" (page 312) provides a list of supported
manufacturers and models. This information is provided on an as-is basis,
to illustrate the eCAP module.
Table 9
Supported manufacturer/model protocols
Manufacturer Model
ARGINA *BASE
ARITECH *BASE
ARITECH 1
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.