User's Manual
309
.
Module - eCAP
The module eCAP consists of the program eCAP.exe, written in Visual
Basic. In general, DECT Messenger programs reside in the default
directory C:\SOPHO Messenger@Net\Exe, unless otherwise implemented
in your environment.
Overview
eCAP.exe
The eCAP.exe is a Visual Basic component of the eCAP module. The
program communicates with two processes: the eKERNEL.exe and an
external alarm interface. The eKERNEL.exe is the central engine that
centralizes all database access and communication with input and output
capable modules.
The eCAP.exe communicates with eKERNEL.exe by means of TCP
sockets. In this communication, eCAP.exe is a TCP client software that
connects to the eKERNEL component, acting as TCP server software.
At startup, eCAP.exe contacts the eKERNEL.exe by means of a socket
connection. Startup parameters identify eCAP.exe, and locate the
eKERNEL.exe program. These parameters are set in the Properties
section of the shortcut that initiates eCAP.exe. This shortcut is usually
located in the Windows Startup group (click
Start on the Windows toolbar,
and choose Programs > Startup).
Figure 63
Typical parameters in the shortcut
In the example shown in Figure 63 "Typical parameters in the shortcut"
(page 309), the eCAP.exe identifies itself as belonging to site 1, and
specifies the location of eKERNEL through IP address *LOCAL and port
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.