Note 1: Broadcast messages pass through both ports simultaneously,
whereas point-to-point messages go out a single port, based on the
address information.
Note 2:
This affects only the configuration of the IP settings of an
FP-1600/2000/2010, but does not affect normal communications.
After configuration, you can use two ethernet cards on a single computer
to communicate to a FieldPoint network module, but only if the cards are
configured with mutually exclusive subnets. This is because point-to-point
communications are transmitted out single ports based on the subnet
masks for the network cards. During configuration the FieldPoint network
modules are not assigned IP addresses, so broadcast messaging is used
through both ports.
Related Links:
Developer Zone Tutorial: Troubleshooting Communication Problems with
the FP-1600 at zone.ni.com/zone/jsp/zone.jsp.
Fixed Version:
Report Date: 09/06/2000
Last Updated: 30/09/2002
Document ID: 1Y8CJDEB
Attachments:
Minimizing and Suppressing Noise (EMI) In the FieldPoint
FP-1600/2000/2010 Ethernet Cable
Product Group: FieldPoint Hardware
Product Name: FP-1600, FP-2000, FP-2010
Version/Revision: N/A