Installing latest firmware 141
and Updates > All Software Versions > Distributed I/O
- Fieldpoint).
2 Download the firmware update utility.
Browse in the list titled Firmware, and:
•
Click
FP-1000/1001 Firmware Revision 30 for Windows
95/98/NT/2000/ME.
• Click continue the download process.
• If are not already logged in, log in to the web site as
prompted.
• Download FPupdate.zip.
• Unzip the archive into your FieldPoint directory.
3 Run FPUpdate to update the firmware.
Close FieldPoint Explorer.
In your FieldPoint directory, navigate to the file, FPUpdate.
Double-click FPUpdate, which brings up the FP-1000/1001
Update dialog box as shown in the following window.
WARNING
Do not interrupt the download.
4 Choose the firmware version you need.
• Click Browse and navigate to the firmware to which you are
upgrading. In this example, the firmware is fpware0.030.
• Set the address and baud rate to correspond with the settings
on your FP-1000/1001.
• Click Download.
5 Verify that the firmware upgrade is complete.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010