User's Manual

Installing latest firmware 137
Use the steps in Procedure 28 “Check which firmware you are currently
using” (page 137) to determine your current firmware revision.
Procedure 28
Check which firmware you are currently using
Step Action
1 Open the Device Configuration dialog box.
Launch FieldPoint Explorer.
Click the + next to IA Server with OPC Server.
Continue expanding the tree until you find your network
module.
Right-click your network module and select Edit this device
in the pop-up menu.
2 Read the firmware version.
In the Device Configuration dialog box, the firmware revision
normally appears in the lower left corner in the form of Firmware
Rev. xxxx, where xxxx represents the firmware revision number
as is shown in the following dialog box.
If the firmware revision does not appear in the lower left corner
of the dialog box:
Continue to step 5.
If the firmware revisions does appear:
Click Cancel to exit.
Continue to Procedure 29 “Determining which firmware you
need” (page 138).
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 1
NN43120-301 02.01 4 June 2010