User's Manual

94 DECT Messenger Customer Engineer Manual
Expand the item Modules > eWEB Module. One instance of
the eWEB module: eWEB - area <x> is shown.
Double-click the eWEB instance to open the parameters/pro
perties. Click IP addresses, as shown in Figure 18 "eWEB
Properties" (page 95).
The first line in the right pane contains the loop back address
(127.0.0.1) of the PC. Do not change this. The second line
contains the correct IP addresses.
Select the second line, and click Edit.
Enter the IP address of the PC where the Apache server
resides in the field: eWEB_address_str.
Enter the IP address of the PC where the eKERNEL resides
in the field: eWEB_ekernel_address_str.
Any data in additional lines is normally not relevant, and can
be deleted.
Note: To delete a line:
select the line.
click Edit.
click Delete.
WARNING
Do not select a line and click Delete, because that
deletes the entire module.
Click OK to save the new settings.
14 Verify the operation of DECT Messenger.
Start the eKERNEL from the shortcut in the Windows Start
menu.
Start the CSTA_Service. This appears in the system tray.
Start the eDMSAPI module.
Open your WEB browser, and enter the correct DNS name
or the IP address of the PC where the Apache WEB server
resides.
Log in with the name that you specified in the table
eWEB_USER_AUTH. The web page opens.
In the left pane, go to Send DMS-API Message. Enter
a message, and select an extension from the list. Note
Nortel Communication Server 1000
DECT Messenger Fundamentals
NN43120-120 02.01
11 May 2009
Copyright © 2003-2009 Nortel Networks
.