User's Manual

150 DECT Messenger Customer Engineer Manual
Telephone Number
The messenger must know what number to dial to access the provider.
(This is not the extension number of the cell phone [GSM phone] to
which the message must be sent.) As example, for PROXIMUS, this
is number 00475161622.
Initialization string
This is the initialization string for modem initialization. The string
depends on the type of modem that you use. A generic modem
initialization string can be for example: AT&C0S0=3. Consult the
modem reference guide for your modem.
Retry Interval
If a message cannot be delivered to the Provider (for example,
because the modem line is busy), the system tries again after the
specified time period.
Send Depth
DECT Messenger collects a number of messages before sending the
messages. Send Depth determines how many messages are collected,
before making a connection to the provider. Default = 1, which means
that messages are processed as soon as they arrive.
Send Time
Time delay before processing received messages. If the Send Depth
is set to a value higher than 1, eaSYNC waits to send the messages
until the number of messages received equals the Send Depth value;
that can take a long time, particularly during off-peak hours. To prevent
DECT Messenger from waiting for a long period, you can specify a
Send Time. After a message arrives, eASYNC waits for the number
of seconds specified in this field, and DECT Messenger sends the
message, ignoring the Send Depth value.
Alarm Priority for DTMF confirmation
This is a priority threshold. If the priority that comes with the alarm
is higher than this threshold, the alarm requires a confirmation from
external. If the Priority is lower that this threshold, the alarm does
not require a confirmation: successfully sending the message to the
SMS Provider makes that the alarm is withdrawn, and not repeated
anymore.
V.24 - RS232 connections (eCAP, eESPA)
The eCAP and the eESPA modules allow you to connect RS232 devices
to DECT Messenger. There is a significant difference between the eCAP
module and the eESPA module. Therefore, these modules are explained
separately in the following subsections.
Nortel Communication Server 1000
DECT Messenger Fundamentals
NN43120-120 02.01
11 May 2009
Copyright © 2003-2009 Nortel Networks
.