Connecting National Instruments modules 123
4 Configure the comm resource
In the Comm Resources Configuration window, set the following:
Name
Accept the default name (FP Res).
Port
This is the COM port on your computer to which you have
connected your V.24 interface from the FieldPoint FP-1000
module.
Baud Rate
Communication speed over the V.24 line. Default this is 115200
b/s. The DIP switch settings associated with the speed are
displayed. Ensure that the DIP switches for the Baud rate on the
FP-1000 module are in the same position as displayed in your
screen. The DIP switches on the FP-1000 module are under a
small cover on the top of the FP-1000 module.