User's Manual
Connecting National Instruments modules 121
Figure 37
Software Parts for the I/O modules
The OPC Server software can be controlled by only ONE application only.
Therefore, you can have either the eIO Module active OR the FieldPoint
Explorer.
Note: Do not forget to close down the FieldPoint Explorer before you
start the eIO module. Conversely, do not forget to close down the eIO
Module before starting up the FieldPoint Explorer.
Procedure 17 “Using the National Instruments FieldPoint Explorer
software” (page 121) describes the steps needed to use the FieldPoint
Explorer software:
Procedure 17
Using the National Instruments FieldPoint Explorer software
Step Action
1 Ensure that the National Instruments FieldPoint Explorer
software is installed correctly.
• Ensure that you have installed the National Instruments
FieldPoint Explorer software as described in the installation
procedure on the CD.
• Verify that the National Instruments FP-1000 is connected to
a free COM port on your DECT Messenger PC.
• Ensure that the eIO Module is not running.
• Open the FieldPoint Explorer window.
2 Open the FieldPoint Explorer.
Nortel Communication Server 1000
DECT Messenger Fundamentals
NN43120-120 02.01
11 May 2009
Copyright © 2003-2009 Nortel Networks
.