User's Manual

12 Nortel DECT Messenger Administrator Guide
Modules overview
DECT Messenger consists of separate modules. There are three main
groups of modules:
Core software modules
Input and output modules
Security modules
The following sections provide an overview of the modules. Detailed
module descriptions are provided in DECT Messenger Installation and
Commissioning (NN43120-301).
Kernel modules
There are two main modules that are used for the core software:
eKERNEL
The eKERNEL is the core software in the system and must always
be present. eKERNEL is between the incoming and the outgoing
modules and must always be running. The system does not operate if
eKERNEL is absent or nonfunctional.
eCONFIG
The eCONFIG module is used to set up and configure the system,
messages, and message flows. The eCONFIG is a user-friendly
variant of the eGRID.
Incoming and outgoing modules
There are nine modules (incoming and outgoing) that communicate with
the eKERNEL module. Incoming modules receive messages and outgoing
modules send messages. Each module has a specific incoming function,
outgoing function, or both. “Incoming and outgoing modules” (page
12) provides an overview of the modules.
Table 2
Incoming and outgoing Modules
Module Name Function Incoming
Outgoing
eCAP V.24/RS232 interface and
protocol converter.
Yes
-
eESPA Input/Output module for the
connection to pager interfaces.
Yes Yes
eAPI Input device for custom-made
programs.
Yes
-
Nortel Communication Server 1000
DECT Messenger Fundamentals
NN43120-120 02.01
11 May 2009
Copyright © 2003-2009 Nortel Networks
.