Connecting National Instruments modules 119
Figure 36 "National Instruments Modules connected to DECT Messenger"
(page 119) shows a configuration of three rails with National Instruments
modules connected to a DECT Messenger. The three rails with modules
are connected together through the RS-485 bus.
Note:
A multi rail configuration is not part of the standard product, and
is only available on a Project basis.
Figure 36
National Instruments Modules connected to DECT Messenger
Note: The connection between the DECT Messenger computer and
the first rail is achieved using V.24. Therefore, the maximum cable
length is determined by the V.24 characteristics and the cable type.
If you have more than one rail (only available on Project basis), the
connection between the rails (and therefore the connection between the
FP-1000 and FP-1001 modules) is achieved using an RS-485 connection.
This is a four wire bus connection that allows a maximum distance of
approximately 1000 metres.
Instead of using an FP-1000 module as Controlling Module on a rail, the
FP-1601 module can be used. The FP-1601 module has an Ethernet
interface to DECT Messenger instead of the V.24 interface. However, this
module is not supported in the standard DECT Messenger product.
Nortel Communication Server 1000
DECT Messenger Fundamentals
NN43120-120 02.01
11 May 2009
Copyright © 2003-2009 Nortel Networks
.