User's Manual

General
DECT Messenger version 4.0 and later require the following firmware on Avaya DECT Mobility
Cards (DMC):
• DMC-4 Firmware: 45100404.dwl firmware
• DMC-8 Firmware: 47000404.dwl firmware
Connection to a DMC
The DECT Messenger Server can be connected to the DMC (DECT system) using a TCP/IP
connection. Verify that your network allows traffic from DECT Messenger to the DMC.
DECT Messenger uses a CTI port to send and receive LRMS messages, requiring one CTI
Messaging Link for each connection to a DECT system. On the DMC card, the default port
number to be used for LRMS Messages is 1025.
To connect to the DECT system you must have the following applications running on your
DECT Messaging Server.
• DECT Messenger eKERNEL
• CSTA_Service (runs in the system tray)
• DECT Messenger eDMSAPI
The CSTA_Service provides the CTI link to the DMC.
Connection to Multiple DECT Systems
To connect to more than one DECT system you must have a CTI link for each DECT system.
Check your license for the number of CTI links available to you.
For each DECT system, you must configure a new eDMSAPI module instance. Each DECT
System must be configured in a different Area, as shown in Figure 18: Connecting to two DECT
systems on page 79.
DECT Messenger Customer Engineer Manual
78 DECT Messenger Fundamentals March 2012
Comments? infodev@avaya.com