User's Manual
This is the message as it is sent to the output device. Note that this message can differ
from the original message. There are two main items that can cause a difference between
the original message and this message field:
- Alarm Length as specified in the Alarm ID definitions.
If the Alarm Length is set to 10 characters, only the first 10 characters of the original
message are regarded as relevant and the remaining characters are stripped off.
- Message Format as specified in the eVBVoice Settings of the Alarm ID in
eCONFIG.
The Message Format allows conversion of the original message.
• MESSAGE Original
This is the original message, as it came from the Input Program.
• ALARM id
The ALARM id is the unique alarm identifier for processing the input request. This Alarm
Identifier, contains parameters on how the alarm must be processed.
• ALARM Prty
Alarm Priority as specified in the Alarm Record for this Input Request.
• ALARM Description
Alarm description that is associated with the ALARM id in the Alarm Record for this input.
Depending on the Input Program type, it provides either the ALARM id or the
description.
• ALARM Remove After
An Input Program provides the Remove After parameter. It indicates whether the alarm
request must stay active until a reset is received from the input program or not.
• GROUP id
The Group id is the Group Identifier that is provided by the Input Program for an Alarm.
In the eKernel, these groups contain one or more Group Members.
• GROUP Description
The Group Description is a recognizable name for the group, and is associated with the
Group id. It is not used for processing the alarm, it is for administrative purposes only.
• DEVICE id
Not yet implemented.
• DEVICE area
Not yet implemented.
• DEVICE Outpgm
Not yet implemented.
• eWEB user
eLOG
DECT Messenger Fundamentals March 2012 149