Configuration Guide
2 • 6
To avoid operational problems and verify that the unit was installed corre c t l y, perf o rm the
following checks.
• Check the unit to transmitter data cable connections. Incorrect cable
connections, together with an incorrect signaling format, are the most
common installation errors.
• Verify that the transmitter and pager frequencies match.
• Ensure that the pagers are at least 10 feet (3 meters) from the transmitter
and antenna.
• Ensure that the pager batteries are installed and the pagers are turned on.
• Ensure the POWER LED lights on both the unit and transmitter are lit. If the
LED lights are not lit, verify the power connections.
• Ensure that the TX LED on the transmitter lights for the duration of
transmission. If not, check the data cables.
• Verify that the unit can pick up a ringing line.
• Verify that the PCI can communicate with the unit
(see section 3.0, Programming the APS Custom).
• Verify that the database was sent correctly.
• Verify that user’s pager CAP codes (Local Pager IDs) were correctly
programmed into the database.
• Verify interface with the PBX - overhead paging, transferring a call, etc.
2.6
Verifying Installation