User's Manual
Avaya Branch Gateway Manager 10.0 Page 80
15-601011 Issue 29r (Friday, November 02, 2012)B5800 Branch Gateway
3.5.2.2 Unsecured Interfaces
This tab is accessible when System is selected in the navigation pane. These features relate to applications that
access the system configuration settings using older security methods.
· System Password: Default = 'password'. Range = 0 to 31 characters.
This password is required by some legacy applications such as Monitor and Call Status. It is also used for control unit
software upgrades.
· VM Pro Password: Default = Blank. Range = 0 to 31 characters.
This password is required if a matching password is also set through the Standalone Voice Mail client application.
Typically no password is set.
· Monitor Password: Default = Blank. Range = 0 to 31 characters.
This password, if set, is used by the System Monitor application. If this password is not set, those applications use the
system password. If changing this password with no previous password set, enter the system password as the old
password.
· Applications Controls: Default = All selected except TFTP Configuration Write.
These check boxes control which actions the system will support for legacy applications. Different combinations are
used by the different applications. A summary of the applications affected by changes is listed in the Application
Support list.
· TFTP Configuration Read: Default = Off.
· TFTP Configuration Write: Default = Off.
· Voicemail: Default = On.
· EConf: Default = On.
· Program Code: Default = Off.
· Real Time Interface: Default = On.
· TAPI: Default = On.
· HTTP Directory Read: Default = Off..
Allow the system's current directory records to be accessed using HTTP.
· HTTP Directory Write: Default = Off.
Allow HTTP import to be used to place temporary directory records into the directory.
· Application Support
This panel is shown for information only. It indicates the effect on various applications of the Application Controls
selections.
174