User's Manual
Avaya Branch Gateway Manager 10.0 Page 422
15-601011 Issue 29r (Friday, November 02, 2012)B5800 Branch Gateway
5.24.1 E911 Adjunct
The settings on this tab relate to the use of an E911 adjunct if installed.
Dial Emergency calls routed to the E911 adjunct include the extension ID of the extension on the system. This is used to
lookup information stored in a database on the E911 Adjunct and then send that information to the central office. The
extension ID of each extension is shown on the Extension | Extn tab.
· To call an extension using its Base Extension number, the short code feature Dial Physical Extn by Id can be
used. This is normally provided by the default short code *71*N# when N can be replaced by the required
extension ID.
Usability
· Mergeable: These settings are not mergeable. Changes to these settings will require a reboot of the system.
Configuration Settings
· Enable: Default = Off (Not Selected)
When selected, all Dial Emergency calls are routed via the selected Adjunct Trunks and includes the extension
ID of the dialing extension.
· Alarm Station: Default = Blank
This is an analog extension port on the system, connected to the alarm switch provided on the E911 adjunct.
When the E911 adjunct detects an error, for example disconnection of the CAMA trunks, it will indicate this by
taking the alarm connection off-hook, making the analog extension busy.
· When an alarm occurs and is indicated to the system by the alarm station being busy, the system will reroute
Dial Emergency calls using the E911 | Zones settings.
· To monitor the status of the alarm connection a user should be associated with the analog extension (one
should exist by default). Another user such as the reception desk or security desk can then be provided with a
programmable button set to the action User and the appropriate user. That button will then indicate busy
when the alarm connection is in an alarm state.
· Adjunct Trunks:
This section lists all the analog and digital trunks (except VoIP trunks) available on the system. Only the trunks
which are connected to the E911 Adjunct should be selected.