User's Manual
Avaya Branch Gateway Manager 10.0 Page 107
15-601011 Issue 29r (Friday, November 02, 2012)B5800 Branch Gateway
Menu Bar Commands: Configuration Mode: File Menu
4.1.8 Advanced
4.1.8.1 Erase Configuration
This command returns the configuration settings of a system back to their default values . It does not affect the
system's security settings or audit trail record.
When this command is used, the Select B5800 menu is displayed. Once a system is selected, a valid configuration user
name and password are required to complete the action.
4.1.8.2 Reboot
When this command is used, the Select B5800 menu is displayed. Once a system is selected, a valid user name and
password are required. The type of reboot can then be selected.
· Reboot
When the reboot occurs can be selected as follows:
· Immediate
Send the configuration and then reboot the system.
· When Free
Send the configuration and reboot the system when there are no calls in progress. This mode can be
combined with the Call Barring options.
· Timed
The same as When Free but waits for a specific time after which it then wait for there to be no calls in
progress. The time is specified by the Reboot Time. This mode can be combined with the Call Barring
options.
· Reboot Time
This setting is used when the reboot mode Timed is selected. It sets the time for the reboot. If the time is after
midnight, the system's normal daily backup is canceled.
· Call Barring
These settings can be used when the reboot mode When Free is selected. They bar the sending or receiving of any
new calls.
4.1.8.3 System Shutdown
This command can be used to shutdown systems. The shut down can be either indefinite or for a set period of time after
which the system will reboot. For Linux based telephone systems, the shutdown command is applied to the telephony
service on the server and not to the whole sever. In that case, if the system is shutdown indefinitely, it can be restarted
using the server's web control pages to either restart the service or to restart the whole server.
! WARNINGS
· A shutdown must always be used to switch off the system. Simply removing the power cord or switching off the
power input may cause the loss of configuration data.
· This is not a polite shutdown, any user calls and services in operation will be stopped. Once shutdown, the
system cannot be used to make or receive any calls until restarted.
· The shutdown process takes up to a minute to complete. When shutting down a system with a Unified
Communications Module installed, the shutdown can take up to 3 minutes while the card safely closes all open
files and closes down its operating system. During this period the module's LED 1 remains green.
57