Configuration manual
These procedures should be performed from a PC with a fixed IP address, directly connected
to the B5800 Branch Gateway control unit and with the B5800 Branch Gateway system
disconnected from any network. The control unit IP address will default to 192.168.42.1.
Important:
Do not perform any of these processes unless absolutely necessary. The configuration
settings can be returned to the default settings using Manager by selecting File > Advanced
> Erase Configuration command.
Erasing the configuration via debug
About this task
This procedure erases the system's configuration settings but does not alter the security
settings. It is easier to use than the boot loader method. Before you perform this procedure,
be sure you have a current backup of the system configuration. See
Creating a backup of the
system configuration using IP Office Manager on page 215 for more information.
Procedure
1. Attach the serial cable between the PC and the DTE port on the control unit.
2. Start the terminal program on your PC.
Note:
Ensure that the DTE port settings are configured as described in RS232 DTE port
settings on page 230. Within a HyperTerminal session, the current settings are
summarized across the base of the screen.
3. Enter AT (upper case).
An OK response appears.
4. Enter AT-DEBUG.
The time and date and then the Hello> prompt appears to show the system is
ready to accept commands.
5. To erase the current configuration in RAM memory, enter eraseconfig.
The Hello> prompt reappears.
6. To erase the backup configuration stored in non-volatile Flash memory enter
erasenvconfig.
The Hello> prompt reappears.
7. To reboot the system, enter reboot.
The system reboots and restarts with a defaulted configuration.
8. Close the terminal program session.
Additional system procedures
232 Implementing the Avaya B5800 Branch Gateway for an Avaya Aura
®
Configuration October 2012
Comments? infodev@avaya.com