Configuration manual
5. Click OK.
Shutting down the system using the System Status application
Procedure
1. Start System Status and access the system status output.
2. In the navigation panel select System.
3. At the bottom of the screen select Shutdown System.
4. Select the time duration for the shutdown or indefinite.
Shutting down the system using a system phone
About this task
To shut down the system using a system phone, you must be administered as a System Phone
user. You can shut down the system using a 1400, 1600, or 9600 series phone (excluding
XX01, XX02, and XX03 models). Unlike Manager, a system phone user cannot select an
indefinite shutdown. A system phone user can set a timed shut down of between 5 minutes
and 24 hours. Your Login Code is used to restrict access to some system administration
functions on the phone.
Procedure
1. Select Features > Phone User > System Admin.
2. Enter your B5800 Branch Gateway user login code.
3. From the menu select System Shutdown.
4. Select a time period for the shutdown. It must be in between 5 minutes and 24
hours.
5. Select Done and then Confirm to begin the shutdown.
Shutting down the system using the AUX button
Procedure
On the control unit, press the AUX button for more than 5 seconds.
System shutdown
Implementing B5800 Branch Gateway for a CS 1000 Configuration October 2012 209