Application Note
FS; Reviewed:
SPOC 06/8/2011
Solution & Interoperability Test Lab Application Notes
©2011 Avaya Inc. All Rights Reserved.
34 of 37
B179-CS1KR75
6.1.2. Verify SIP Registration Status
In the Element Manager web interface, navigate to System IP Network Maintenance and
Reports on the left pane. Click GEN CMD.
The General Commands page is displayed. From the Group drop-down menu select SipLine,
from the Command drop-down menu select slgSetShowByUID, enter the B179 extension in
UserID, and click on RUN. The output shown indicates successful registration and displays
details of the registration parameters. Note that if the B179 has not registered, the error message
“Invalid userId 57010” will be returned instead of the detailed registration information.