3.5. Configure Application Module Link (AML)
On the left column menu of the main Element Manager page, navigate to System Interfaces
Application Module Link, and click Add (not shown). The New Application Module Link
page is displayed. Enter the AML port number in the Port number text box. The SIP Line
Service can use ports 32 through 127. In the sample configuration, the SIP Line Service is
configured to use port 32. Enter an appropriate Description. Click Save to save the
configuration.
3.6. Configure Value Added Server (VAS)
On the left column menu of the main Element Manager page, navigate to System Interfaces
Value Added Server. Click Add and then click Ethernet LAN Link on the Add Value
Added Server page that is displayed next (not shown). On the Ethernet Link page that is
displayed next (not shown), enter a Value added server ID (64 in the sample configuration),
and select the AML number created in the previous section for Ethernet LAN Link. Ensure
that the Application Security check box is unchecked. Click Save (not shown). The screen
below shows the result of adding the value added server.