Release Notes

30
311708-A Rev 00
CR 126173-1: Frame relay
When you delete a frame relay circuit, some frame relay objects are not deleted.
CR 126750-1: IP
Using Site Manager to configure an IP interface causes IP to go down globally on
the router (backward-compatibility issue).
CR 128472-1: AIX
When you try to add a dialup circuit to a local configuration file with the AIX
version of Site Manager, a core dump is produced and Site Manager terminates
without updating the configuration.
CR 128765-1: Image Builder
When you use the Image Builder with the AIX version in Site Manager, Site
Manager does a core dump in the builder module when you use Save As.
CR 128788-1: Build
Customer needs a BN software image without FRE4 images. This image is
available in the new corpfre2_suite directory.
CR 129653-1: IP
Customer needs an enhancement to interrupt customers with an error message to
check the configuration before continuing an announce policy with an empty
network list.
CR 130000-1 IP traffic filters
When a filter is deleted and a change was made to another filter, Site Manager
creates an invalid IP traffic filter entry.
CR 130453-1: SM_CORE
Site Manager on the Windows platform hangs when accessing Port Details >
Line Tests > Logical lines.
CR 132772-1: IPX
Adding VRRP to an interface with IPX causes IPX to stop routing.