Release Notes
28
311708-A Rev 00
CR 117213-1: Statistics Manager
There is a misaligned column in the Statistics Manager screen CSMA/CD Misc
Errors.
CR 117294-1: OSPF
When the OSPF global parameter Multicast Extension is set to any value but
None, several fields are not available within the Site Manager interface.
CR 117310-1: OSPF
The virtual interface configuration screen for OSPF does not display the correct
detail information for the fields Transit Area ID and Neighbors Router ID.
CR 117645-1: Events Manager
The number of records shown in the Events Manager is less than the number of
records actually being displayed.
CR 117873-2: SDLC
When you configure multiple local devices for SDLC and DLSw, the MIB
attribute wfSdlcLSAdminRole is set to the default after the first device is created,
if you selected DLSw mode of Secondary. The MIB attribute
wfSdlcLSAdminRole should also be set to Secondary.
CR 118255-1: Configuration Manager
When you use the Configuration Manager in remote mode to configure a router,
and then save the configuration file, it is not transferred to the router that you are
trying to configure.
CR 118446-1: DVMRP
On a router that has OSPF and DVMRP configured on an interface, if you use Site
Manager to delete and then add DVMRP, DVMRP does not appear to be
configured.
CR 118542-1: ATM
When configuring an ATM circuit dynamically with Site Manager, you must click
on the Delete button twice to delete a service record when the fiber is
disconnected and a service record has been added.