User's Manual

84 Administering Avaya Video Conferencing Solution 6.0.1 Issue 2.1 April 15, 2011
Note:
Note: If the VSX system has the multipoint option or IMCU option, enter add station
to add a second station for the Polycom system. The extension number should
be one greater than the station added in the previous step. Set the following
parameters:
Type : H.323
Security Code : pin you will administer for the VSX/HDX. Ensure the security code is
the same as the previous station. Each station configured for the multipoint device
must use the same security code.
IP Video : Y
Repeat step 4 to create the third consecutive station. You can have up to seven stations.
4. Enter change station n (where n is the first station you added for the Polycom system)
to set Hunt-to Station to the second station you added for the Polycom system.
5. Enter change station n (where n is the second station you added for the Polycom
system) to set Hunt-to Station to the third station you added for the Polycom system.
6. Enter change station n (where n is the third station you added for the Polycom system)
to set Hunt-to Station to the first station you added for the Polycom system. All three
stations must be in a circular hunt.
Note:
Note: If you added more than three stations for the Polycom system, use the station
screen to set Hunt-to Station for each station. All the stations you add must be
in a circular hunt.
Configuring a Polycom RMX Series Video Conferencing Bridge
Platform
This section describes how to configure a Polycom RMX series video conferencing bridge
platform for use with an Avaya server.
Checklist
When setting up these systems, you will need to know the following information:
the IP codec sets you want to use
the IP network regions you want use
the IP address of the IP board for the RMX system