Specifications
26
AVANTI Service Lift for Wind Turbines
3.24 Anchor points for PPE
The service lift is equipped with two anchor points
inside the cabin in bucket type version and three
anchor points in full sliding door versions. In case of
evacuation, the evacuation procedure must be
followed (see “Appendix A: Safety measures”).
3.25 Information signs and documents
The following documents, signs and stickers are
supplied with the service lift and shall always be
available.
3.26 Internal light
1)
The service lift is equipped with a light inside the cabin.
When service lift is connected to power supply, this
light illuminates at all times.
The internal light is battery packed in order to illumi-
nate the inside of the cabin in case of a power failure.
When fully charged, it will last at least for 30 minutes.
3.27 Warning lights
1)
A set of warning lights is mounted on the top and on
the bottom of the service lift. The flashes warn that the
service lift is moving.
3.28 Platform fences
The platform fences protect users from falling through
the service lift hole at platforms.
These platform fences shall comply with:
• EN 14122-3 for Pegasus CE bucket type version.
They shall have non-slip rails or steps facilitating
access to the lift and to the guiding ladder from
the platforms and shall have no doors.
• EN 14122-3 for Pegasus CE full sliding door
version. They shall feature a fence door monitored
by a guard locking system, or a trapped key
system, preventing any movement of the lift if the
fence doors are not closed and locked.
• 5.11 of ASME A17.1-2012/CSA B44-13 for Pegasus
AECO version. Given that call function is included,
the fence doors shall be monitored by a guard
locking system, or a trapped key system, prevent-
ing any movement of the lift if the fence doors are
not closed and locked.
4. Instructions for use
4.1 Cautions
Aspects to consider for a good use of the service lift:
1. No person is on the ladder when the service lift is in
operation.
2. The service lift is free of objects.
3. No objects are located on the top of the cabin.
4. Electrical system is properly insulated.
TOP ANCHOR
POINT (S)
BOTTOM
ANCHOR POINT
Document Position
Serial number plate Inside the cabin.
Manual Inside the blue bag.
Quick guide Inside the cabin.
Use of PPE sticker On the motor cover.
Work load / Nº persons sticker On the front side of cabin.
Warning risk of falling sticker On the motor cover.
Warning risk of crushing sticker (x2) On the pinion covers.
Manual descent sticker On the motor cover.
Wiring diagram Inside the bottom platform control box.
Eletrical warning disconnection sticker On the bottom platform control box.
UL sticker
2)
Electric warning disconnection sticker Underneath the cover of the bottom
platform control box.
Alignment stickers Inside the cabin and at each landing
Lubrication sticker On the motor cover.
No standing on top prohibition sticker
1)
On the front side of the cabin.
Top clearance sticker
2)
On the front side of the cabin.
Maintenance brake sticker
2)
Inside the cabin.
Measurement of pinion and rack
2)
Inside the cabin.
AECO Data plate
2)
Inside the cabin.
Jurisdictional Code Data plate
2)
On the motor cover.
Pull to release sticker
2)
On the cabin control box.
Electrical hazard sticker On the cabin control box.
Electrical hazard sticker
2)
On the weighing module box.
Each anchor point may only be used by one
user simultaneously.
STOP
STOP
Ladder and rest platforms must be used only for
evacuation or when the service lift is out of service.
In bucket type version: users inside the cabin shall
be attached to an anchor point when door is open.
In full sliding door
1)
version: users inside the cabin
shall be attached to an anchor point at all times.
1)
Optional for CE versions. Mandatory for AECO
version.
2)
Not applicable to CE versions. Mandatory for
AECO version.