INSTRUCTIONS BEFORE USING YOUR NEW HYTORC -continued from the previous
page-
2-3 ELECTRICAL CONNECTIONS Ensure
p
ro
p
er
p
ower availabilit
y
to
p
revent motor failure or
dangerous electrical overloading. Compare the motor nameplate for required amperage. Do not use
electric pump, if three prong electrical plug is not whole. Minimize the len
g
th of extension cords and be
sure they are of adequate wire size, with ground connectors. Extension cord up to 50 feet should be #10
AWG gauge.
CAUTION: Electric motors may spark. Do not operate in an explosive atmosphere or in the presence
of conductive liquids. Use an air pump instead.
2-4 AIR CONNECTIONS Ensure that you have sufficient air flow of 80 psi ( 50 cfm) to operate your
pneumatic pump. If in doubt, compare the pump manufacturer’s recommended air flow rating prior
to pressurizing pump. Improper air flow may damage the pump motor. For best results, use air hose
larger than 3/4 “ diameter.
Use of a filter regulator lubricator (FRL) is highly recommended. (diagram below)
1. Adjust flow to 1-2 drops per minute.
2. Fill half way with grade 46 hydraulic oil supplied.
AIR FLOW
ON/OFF LEVER
AUTO WATER DRAIN PORT
CONDENSATION
BOWL
AIR ADJUSTMENT KNOB
OIL LUBRICATOR
ADJUSTMENT KNOB
FILTER CAP
DRIER
AIR PRESSURE GAUGE