Specifications
PAGE 36 OPTIONAL EQUIPMENT (CONTINUED)
45° Flue Adapter (Part # 98900119)
The 45° flue adapter is designed for insert installations requiring a more flexible flue outlet.
1 Install the flue adapter prior to inserting the insert into the fireplace.
2 Follow the instructions below to install.
1/4" Nutdriver
Unscrew the eleven
screws to remove the
draft hood.
Draft Hood
Remove the spill switch bracket by
removing the two attachment screws
(keep the two wires attached).
Phillips
Screwdriver
a
b
Once installed, the vent is located
1-1/8" forward and 17-5/8" above
the rear edge of the insert.
45° Draft Hood
e
d
Place the 45° draft hood over the
convection channel and attach
with the eleven screws removed
in step "b".
17-5/8"
1-1/8"
Attach the spill switch to the
45° draft hood with the two
screws removed in step "a".
c
1/4" Nutdriver
Remove and discard this baffle
(use a 1/4" nutdriver to remove).
Replace the screws to seal the
exposed holes.