Specifications
LISTING INFORMATION PAGE 33
The safety label can be found on a card that is chained to the unit behind the control cover. A copy is shown
below.
Input and Orifice Specifications: L.P. N.G.
Maximum Input Rating (BTU/Hr) 38,000 40,000
Minimum Input Rating (BTU/Hr) 20,000 23,000
Burner Orifice #49 #31
Pressure Specifications: L.P. N.G.
Manifold Pressure HI Setting (W.C.) 10” 3.5”
Manifold Pressure LO Setting (W.C.) 2.7” 1.0”
Minimum Inlet Pressure (W.C.) 11” 5.5”
Minimum Clearance to Combustibles
Unit to Sidewall....................................... 10”
Unit to Backwall...................................... 4”
Unit to Cornerwall................................... 4”
Alcove Minimum Width.......................... 44”
Alcove Minimum Height......................... 58”
Alcove Maximum Depth......................... 45”
Side Facing ............................................. 8”
Top Facing .............................................. 12”
Mantle Height Above Unit ............... 17-1/2”
Hearth Extension (Front) ....................... 0”
Hearth Extension (Side)......................... 0”
Blower Electrical Rating: 115 Volts, 1.5 Amps, 60 Hz.
FAN TYPE VENTED CIRCULATOR
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting
system or tampering with the vent safety shutoff system can result in carbon monoxide (CO)
poisoning and possible death.
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to the information in the owner's manual provided with this appliance.
For assistance or additional information consult a qualified installer, service agency or the gas
supplier.
Risk of electrical shock. Disconnect power before servicing unit.
Do not route power cord beneath heater when installed as an insert.
This room heater needs fresh air for safe operation and must be installed with provisions for
adequate combustion and ventilation air. See owner’s manual and operating instructions.
DO NOT REMOVE THIS LABEL
Avanti Gas Heater
Listed Gas-Fired Vented Room Heater
10850 117th Pl. N.E. Kirkland, WA 98033
MADE IN THE U.S.A. BY:
MANUFACTURE DATE:
1996
1997 Jan. Apr. Jul. Oct.
1998 Feb. May Aug. Nov.
1999 Mar. Jun. Sep. Dec.
Tested to ANSI Z21.11.1-1991, ANSI Z21.11.1a-1993, CAN/CGA 2.1M88, CAN/CGA 2.17M91
By OMNI Environmental Services (Report #028-S-08-5, January 1996)
Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 in USA, CAN B149 in
Canada, and the requirements listed in the accompanying owner's manual.
Electrical connections and grounding must be installed in accordance with local codes, if any; if not, follow
ANSI/NFPA 70 in USA or CSAC 2.21 in Canada.
Controls: Robertshaw Model 7000MVRB-5-LC
This room heater is equipped at the factory for use with natural gas, if conversion to propane (LP) fuel is
desired, the optional factory conversion kit #98900745 must be used.