Specifications

53Digital Family Features
Software upgrades
When Telrad develops new software for the Avanti
3025, Avanti 3020F, Avanti 3020H, Avanti 3015DF,
Avanti 3015DH, and Avanti 3015H telephone sets, the
software can be downloaded to the telephones from a
remote sight or from a PC connected to the MPD card
in the system cabinet. The technician can specify that
the download be done to these telephones system-wide,
to all of a specific model of Avanti telephone, or to
one specific telephone. This upgrade of the telephone
software is quick and does not disrupt the whole
operation of your office, since it is done without
touching the telephones.
Station Message Detail Recording (SMDR)*
Details of all incoming or outgoing calls can be directed
by the system to a printer or call accounting system.
Both parameters of calls to be recorded (such as number
of dialed digits or call duration) and transmission
parameters of the SMDR device (such as baud rate and
parity) can be programmed (see also Integrated Station
Message Detail Recording, in Section 6, ImaGEN
Application Generator and Other Optional Features,
above).
Station self-test
Automatic station maintenance tests check the operation
of the buttons on the telephone set and the telephone
set hardware.
System speed dial
Each class of service can access up to ten system speed
dial groups. Each group can have up to 100 numbers.
The DIGITAL KEY BX and DIGITAL 400 systems
support two speed dial arrays, each with up to 10
system speed dial groups and 1700 (DIGITAL KEY
BX) or 2700 (DIGITAL 400) system and personal
speed dial numbers. The DIGITAL 1000 system
support four speed dial arrays, each with up to 10
system speed dial groups and 2700 system and personal
speed dial numbers.
SYSTEM TIMERS
Different times may be set for the following time
parameters:
Attendant interflow timeout
Attendant overflow timeout
Attendant recall
Automatic EHU printout
Automatic test start
Barge-in tone
Call forward no answer
Call record warning tone
CENTREX flash
CO signal flash
Conference loop force connect
Day recall
Delayed ringing
Dialing pulses per second
DTMF dial-off duration
DTMF dial-on duration
First digit timeout
Forced onhook
Handsfree
Hold
Hunt no answer
ISDN 302
Make/break ratio
Maximum interdigit dialing
Night recall
Open loop
Page
Patch
Pause
PBX feature flash
Preferred connection
Reset after swap (DIGITAL 1000 only)
SLT interdigit
SLT maximum flash
SLT near end disconnect
Transfer recall
* Requires the ImaGEN option