Specifications

Placing Conditioner into Operation
After all previous steps have been completed, the unit is ready to be
placed into operation. Follow these steps carefully.
1. Remove control valve cover by rst depressing the plastic clips
from the front of the cover. Pull front of cover up.
Note: The following steps will require turning the cycle indicator
(Figure 6) to various positions. Manually rotate the camshaft
COUNTERCLOCKWISE only until cycle indicator points to desired
position. (See manual regeneration sections for each control’s
manual operation.)
2. Rotate cycle indicator
COUNTERCLOCKWISE until it points directly
to the word BACKWASH.
3. Fill media tank with water.
With water supply off, place the bypass valve(s) into the “service”
position.
A. Open water supply valve very slowly to approximately the 1/4
open position.
IMPORTANT: If opened too rapidly or too far, media may be lost. In the
1/4 open position, you should hear air escaping slowly from the drain
line.
B. When all of the air has been purged from the tank (water
begins to ow steadily from the drain), open the main supply
valve all the way.
C. Allow water to run to drain until clear.
E. Turn off water supply and let the unit stand for about ve
minutes. This will allow all trapped air to escape from the tank.
4. Add water to brine tank (initial ll).
With a bucket or hose, add approximately
4 gallons (15 liters) of water to brine tank. If the tank has a salt
platform above the bottom of the tank, add water until the level is
approximately
1 inch (25 mm) above the platform.
5. Place the conditioner into operation.
A. With the water supply valve completely
open, carefully advance the cycle indicator
COUNTERCLOCKWISE to the center of the
BRINE REFILL position. Hold at this position
until water starts to ow through the brine line
into the brine tank. Do not run for more than
one or two minutes.
B. Advance the cycle indicator
COUNTERCLOCKWISE until it points to the
center of the BRINE/SLOW RINSE position.
C. With the conditioner in this position, check to
see if water is being drawn from the brine tank.
The water level in the brine tank will recede very
slowly. Observe water level for at least three
minutes. If the water level does not recede,
or if it goes up, reference the Troubleshooting
section.
D. Advance the cycle indicator
COUNTERCLOCKWISE to the SERVICE position
and run water from a nearby faucet until the
water is clear and soft.
Electrical Connection