Installation manual

Installation (for qualified installers only) 7
© Travis Industries 4050714 100-01173_001
Packing List
Propane Conversion Kit
Log Set
Wall Switch with Wire (see page 19 for details)
Firestop (sku 93006094)
Additional Items Required
Direct Vent
Gas Line Equipment (shutoff valve, pipe, etc.)
Electrical Equipment (min. 14 gauge, grounded line)
Installation Overview
All requirements below must be met.
See the section
"Approved Vent
Configurations"
See the section
"Electrical Connection"
See the section
"Mantel Requirements"
Insulation must not fill
the 1/2" clearance
around the back and
sides of the fireplace.
See the section
"Vent Requirements"
See the section "Minimum
Framing Dimensions"
Drywall
T
op Vent
C
onfiguration
Rear
Vent
Configuration
See the section
"Gas Line Installation"
1" Min.
Side
Wall
See "Optional Non-
Combustible Facing"
Drywall
See "Optional Non-
Combustible Hearth"
Nailing Brackets
Required Travis
Firestop (sku
93006094)
Recommended Installation Procedure
Frame the opening for the fireplace. Make sure to allow for vent installation.
This fireplace is designed to accommodate 1/2" or 5/8" drywall (see "Nailing Brackets" on
page 13 for details). Secure the fireplace to the framing.
Install the vent, gas line and electrical hook-up.
Install the wall switch (see page 19) or thermostat (if applicable).
Install the drywall.
Install the hearth (if applicable).
Install the facing (if applicable).
Install the mantel (if applicable).
Finalize the installation (see page 42) and install the grill or face.