Wiring Instructions
Warning: All wiring should be done by a qualified electrician and shall be in compliance
with local codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or with
the current CSC22.1 Canadian Electric Code (in Canada).
Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical
hookup.
Wiring Diagram -864TRV
Hot
(black)
Common
(white)
Ground
(green)
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Rheostat
Junction Box
Blower
Assembly
1 Follow the directions below to wire the blower box.
Remove the cover from
the blower box.
a
b
Insert sheathed cable through the cable clamp.
After the wires have been connected tighten the
clamp to secure the cable.
Secure the ground wire to the ground stud inside the
blower box by tightening the included nut over the
ground wire. Re-attach the cover removed in step
"a".
Attach the hot (black) and common (white) wires to the
leads coming from the wires (use wire nuts).
c
d
Standard
Screwdriver
Phillips
Screwdriver