Installation manual
62 Optional Equipment (for qualified installers only)
Travis Industries 4050714 100-01173_001
Extra Room Power Heat Duct
Installation Overview
The optional heat duct allows the fireplace to transfer heat to separate locations in the home.
Installation should take place prior to installing drywall.
Warning: This kit must be installed as specified in these instructions. Do not modify any
component.
Warning: Use of any external blower other than the Travis Power Heat Duct Blower will void
the warranty and listing of this appliance and may create a fire hazard.
Note: The power heat duct must be installed by a qualified service technician.
Note: Some building codes may require the use of firestop spacers whenever the duct passes from
room to room.
Note: When routing ducts through a cold area (e.g. crawl space) we recommend insulating the
duct with fiberglass insulation. If paper-backed insulation is used, the paper can not contact the
duct.
Starter Ring
Use 10” x 3-1/4”
wall stack (duct)
when passing
through tight
areas.
6" Duct
Duct Adapter
(6” Round to 10” x 3-1/4”)
Floor
Boot
Grill
Rheostat
(with cover plate)
Junction Box
Wall Adapter
(for use on
2 x 4 walls)
Blower
Box
Maximum Duct
Length = 20'
Electrical Source