6 Features and Specifications
Travis Industries 4050714 100-01173_001
Installation Options
• Residential or Mobile Home
• Straight or Corner Placement
• Flush or Recessed Face
• Raised or Floor Placement
• Internal or External Chase
• Horizontal or Vertical Vent
• Bedroom Approved
Heating Specifications
Natural Gas Propane
Approximate Heating Capacity (in square feet)* 450 to 1,400 450 to 1,400
Maximum BTU Input Per Hour 31,000 31,000
Minimum BTU Output on Low 6,700 5,200
Steady State Efficiency** (with blowers on) 77.2 % 78.4 %
AFUE (Annual Fuel Utilization Efficiency) 68.3 % 69.4 %
* Heating capacity will vary with floor plan, insulation, and outside temperature.
** Efficiency rating is a product thermal efficiency rating determined under continuous
operation independent of installed system.
Dimensions
* Includes the required 1/2" clearance.
Rear Vent Configuration
8" Diameter Vent
30-3/4"
Back of Fireplace
38-1/4"
36-3/4"
41"
19-3/4"*
38-3/8"
29-1/4"*
Top Vent Configuration
8" Diameter Vent
Weight: 205 Lbs.
37"
1"
35-1/4"
7-1/4"
Optional "Extra Room
Power Heat Duct"
Connection