Installation manual

Installation (for qualified installers only) 11
© Travis Industries 4050714 100-01173_001
Minimum Framing Dimensions - Rear Vent Configuration
Route the
electrical line to
a position to the
left rear of the
fireplace.
Vent Clearances (8" dia. Vent):
1" to the sides, 1" below, and 3" above
the vent to combustibles.
Included Firestop (required)
Part # 93006094
Center of Rear Vent
30-3/4"
38"
41-1/4"
38-1/2"
20"
WARNING: A cut-out for the gas line
may be required on the framing. See
the dimensions under"Gas Line
Connection" for details.
HINT: place the fireplace so the center
line is at least 5" from both vertical framing
members at the rear (this allows the vent
to pass through the framing without
modfications)
25-3/4"
The on/off switch/thermostat wire (if
used) should be routed to a location
near the right front of the fireplace.
Minimum enclosure height = 38-1/2"