Installation manual
Fireplace Specications
Hideaway
TRV
Seattle
Space Saver
Height - including standoffs
Width
Depth
Flue Diameter
Unit Weight
Burner System
Glass Area
Powerful Fan
Power Heat Duct Option
Specifications
The dimensions and clearances on this page are for reference only. Refer to the Owner’s Manual prior to installation.
Performance
Combustible Clearances
Always consult the Owner’s Manual before beginning any installation. Installation and framing information is available at your local Avalon
dealer or on our website at www.avalonfirestyles.com
33 1/4”
36 1/4”
16 1/4”
8”- Top Vent
reduces to 6 5/8”
155 lbs.
2 Stage Pan Burner
31 3/8” W x 18 1/8” H - 564 sq. in.
180 CFM - Optional
No
A= 38 1/2”*
Measured from base of fireplace
B= 0”
C= 1”
D = 0”
E = None Required
F = None Required
* Will vary depending on * * * *
* mantle depth. 0 to 12”
* maximum mantle depth.
* See Installation and Owner’s
* Manual for details.
Tested and Listed by OMNI-Test Laboratories, Inc. or Intertek Testing Service to ANSI Z21.88b-2001 “Vented Gas-Fired Direct Fireplace Heater.”
Must be installed in accordance with all local codes, if any: if not, follow ANSI Z223.1 and the requirements listed in the Owner’s Manual.
All measurements are taken
from the fireplace face.
A= To Mantle
B = To Top Facing
C = To Sidewall
D=To Side Facing
E= Front Hearth
F = Hearth Width
The Hideaway fireplace requires
a 1” minimum clearance from
face to sidewall. Combustibles
can be installed up to the stand-
offs on the unit. If a mantle is
used please see Owner’s Manual
for minimum clearances.
The height of the Hideaway
fireplace enclosure must be a
minimum of 48” above the base
of the fireplace.
If placed on a raised hearth, the
ceiling above the Hideaway must
be at least 57” measured from the
base of the fireplace.
35 7/8”
20 1/8” Front
13 1/2”
8” (Top Vent
reduces to 6 5/8”)
97 lbs.
Ember-Fyre
17 5/8” W x 23 1/4” H - 394 sq. in.
90 CFM - Optional
No
Avalon
GreenSmart
Gas Fireplaces
25
Seattle
Diamond-Fyre
33 1/4”
36 1/4”
16 1/4”
8” - Top Vent
reduces to 6 5/8”
155 lbs.
2 Stage Pan Burner
31 3/8” W x 18 1/8” H - 564 sq. in.
180 CFM - Optional
No
A= 38 1/2”*
Measured from base of fireplace
B= 0”
C= 1”
D = 0”
E = None Required
F = None Required
* Will vary depending on * * * *
* mantle depth. 0 to 12”
* maximum mantle depth.
* See Installation and Owner’s
* Manual for details.
Note: Each face plate design
varies in dimension slightly
Heating Capacity*
Input High/Output Low NG*
Input High/Output Low LP*
Steady State Efficiency*
P4 Canadian Efficiency
*Gas appliance performance can be affected by negative pressure in the home and by prevailing atmospheric conditions. Efficiency may vary depending on vent configu-
ration and atmospheric conditions. Contact local building or fire officials about restrictions and installation requirements in your area.
Up to 950 Sq. Ft.
20,500 (H) 5,100 (L)
20,500 (H) 4,200 (L)
76.5% NG, 78.3% LP
67.7% NG, 70.11% LP
Up to 650 Sq. Ft.
16,500 (H) 3,780 (L)
16,500 (H) 3,150 (L)
82.2% NG, 79.5% LP
65.2% NG, 68.97% LP
Up to 950 Sq. Ft.
20,500 (H) 5,100 (L)
20,500 (H) 4,200 (L)
76.5% NG, 78.3% LP
67.7% NG, 70.11% LP