Owner`s manual

Safety Label 39
© Travis Industries 4090901 100-01224_000
Safety Label
The safety (listing) label is on the back of the stove. A copy is shown below.
Report No. B0490PRT-001 / Control No. 4000515
Certified for US and Canada
Vented Gas
Fireplace Heater
Tree of Life GS
Tested to: ANSI Z21.88-2009/CSA 2.33-2009 “Vented Gas Fireplace Heaters”, CGA 2.17-M91, UL 307b-1995 “Gas
Burning Heating Appliances for Manufactured Homes”, and CSA P.4.1-09.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing, in
Canada or with the Manufactured Home Constructions and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation
Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is
desired, the optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured home (USA only) where not prohibited by local codes. See owner’s manual for
details. This appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation
instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior. See owner’s manual
for approved brands of venting.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with this appliance. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
CAUTION: Hot while in operation. Do Not Touch. Severe burns may result. Keep children,
clothing, furniture, gasoline and other liquids having flammable vapors away. Do not operate
this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
MINIMUM CLEARANCES TO COMBUSTIBLES
Stove Top to Sidewall
Stove Top to Backwall
Stove Top to Cornerwall
Glass Front of Unit
10” (254 mm)
5” (127 mm)
5” (127 mm)
36” (914 mm)
Alcove Min. Height
Alcove Max. Depth
Alcove Min. Width
58” (1473 mm)
45” (1143 mm)
46-3/4” (1187 mm)
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
31,000
12,600
31,000
10,700
Minimum Inlet Pressure (inches W.C.)
Maximum Inlet Pressure (inches W.C.)
Manifold Pressure on “HI” (inches W.C.)
11
13”
10”
5.5”
7”
3.5”
For natural gas when equipped with the following drill size orifice: DMS 50 Front - 47 Rear
For propane when equipped with the following drill size orifice: DMS 56 Front - 56 Rear
This appliance is equipped for use only at altitudes 0-2000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m).
For altitudes above 2000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner’s manual for information on making these changes.
Electrical Rating: 115V., 60 Hz, 1.5 Amps
Optional Blower: SKU # 99000159
L.P. N.G.
L.P. N.G.
2010
2011
2012
Jan.
Feb.
Mar.
Apr.
May
Jun.
Jul.
Aug.
Sep.
Oct.
Nov.
Dec.
Manufacture
Date:
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
www.travisproducts.com
0826