Owner`s manual
Installation (for qualified installers only) 9
© Travis Industries 4091026 100-01238_000
Installation Hints:
• Recommended Optional Equipment Installation Order:
-- GreenSmart Remote
-- Blower
-- LP Conversion and other optional equipment
• Install the logs last - they are fragile.
• When determining the location of the stove, locate the wall studs (for horizontal penetrations) and
ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure
the vent does not intersect with a framing member.
• Fumes and smoke from the paint curing and oil burning off the steel may occur the first time you start
this heater. This is normal. We recommend you open windows to vent the room.
Stove Clearances
NOTE: If using the rear vent configuration, you will require approximately
8-1/2” to the rear of the stove for the vent adapter and thimble. See page
18 for details.
3-1/2" Min.
89mm
Straight Installations Corner Installations
With this clearance, the vent is
centered 10-1/4" (260mm)
from the wall.
With this clearance the top vent is
centered 8" (203mm) from the
back wall, 14-1/4" (362mm) from
the side wall.
5" Min.
127mm
(See note above
regarding rear vent
configurations)
1" Min.
25mm
45°
Mobile Home Requirements
• When the stove is installed in a mobile home, it must be bolted to the floor and the appliance
grounded (use the optional blower with a grounded circuit or other suitable grounding method -
current ANSI/NFPA 70 or CSA C22.1).