Owner`s manual

Installation (for qualified installers only) 21
© Travis Industries 4091026 100-01238_000
Rear Vent Configuration Vented into Fireplace with Co-Linear Adapter
Attach the Co-Linear adapter directly to the back of the stove. Use two (2) 3” flex vents to vent
the appliance through a code-conforming masonry or metal (zc) fireplace. All clearances to
combustibles must be met and the flex vent must be vented through a non-combustible fireplace
chimney.
Use a high-wind termination cap.
Vent height must be a minimum 10’ and maximum 25’.
Diffuser must be set to closed (#2) position.
Intake and exhaust restrictor must be set to the #1 (stock) position.
Do not install the intake damper plate or exhaust restrictor extender plates.
Flashing and Adapter
#991 High Wind
Termination
Co-Axial to Co-Linear Adapter
High-Temp.
Silicone
3" (77mm) Dia. Flex Line
Min. 18"