Owner`s manual
18 Installation (for qualified installers only)
© Travis Industries 4091026 100-01238_000
Rear Vent Configurations with Horizontal Termination and No Rise
• Use 8” Diameter Vent with a 6-5/8” to 8” adapter (increaser). We recommend using the minimum
vent kit from Travis Industries (SKU 96200311). This kit contains the following components used
to vent the stove through a typical exterior wall:
-- 6-5/8” to 8” Adapter (Black)
-- Thimble
-- Thimble Cover (Black)
-- Pipe (3.9”)
-- High-Wind Horizontal Cap
• Place the 6-5/8” to 8” adapter directly onto stove (see illustration below).
• Maximum Horizontal Run of 4’.
• Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.
• Maximum of one (1) 45° elbow may be used between horizontal sections.
• Diffuser must be set to closed (#2) position.
• Intake and exhaust restrictor must be set to the #1 (stock) position.
• Do not install the intake damper plate or exhaust restrictor extender plates.
6-5/8" to 8" Adapter
High Wind Horizontal Cap
Required (58DVA-HC)
Typical 8-1/2" (216mm)
Min. 12" (305mm)
Grade
Thimble w Cover
Max. 4' (1.2M)